Termosol 1 CSP Project

This page provides information on Termosol 1 CSP project, a concentrating solar power (CSP) project, with data organized by background, participants, and power plant configuration.

Project Overview

Power Station: Termosol 1
Location: Navalvillar de Pela
Badajoz
Extremadura Spain
Owners (%): NextEra, FPL
Technology Parabolic Trough
Solar Resource: 2077
Nominal Capacity: 50 MW
Status Operational
Start Year: 2013

Status Date

Status Date

Background

Break Ground Date 2011
Expected Generation (GWh/year) 180
Lat/Long Location 39.193,-5.576
Total Power Station Land Area (km²) 2

Participants

Developer NextEra, Florida Power & Light
USA
EPC Sener
Spain

Costs

Total Construction Cost (2013) € 409.50 million
Total Cost USD (2020) $587.82 million
Specific Cost/kW USD (2020) $ 11756.3
LCOE USD/kWh (2020) $ 0.28
Levelised cost of electricity with 5% weighted average cost of capital and a 25 year payback period, capacity dependent O&M (1.5% of investment cost per year), deflated from Year_operational using the Worldbank's GDP deflator; if station under development or construction then not deflated (assumed cost year 2020)
Remuneration EUR/kWh 0.27
Remuneration Start Year 2013
Remuneration USD/kWh Deflated (2020) 0.39
PPA or Tariff Period (Years) 25
Support Scheme Type FIT
Policy Support Scheme Real Decreto 661/2007

Plant Configuration

Solar Field

Solar Field Aperture Area (m²) 523200
# of Solar Collector Assemblies (SCAs) 640
# of Loops 160
# of SCAs per Loop 4
SCA Aperture Area (m²) 817
Collector/Heliostat Manufacturer Sener
Spain
Collector/Heliostat Engineering or IP Owner Sener
Spain
Collector/Heliostat Model SenerTrough
Mirror Manufacturer Flabeg
Germany
Mirror Model RP3

Solar Field (Receiver)

Receiver Working Fluid Thermal Oil
Receiver Working Fluid Category Thermal oil/organics
Solar Field or Receiver Inlet Temperture (C) 293°C
Solar Field or Receiver Outlet Temperture (C) 393°C

Power Block

Nominal Turbine or Power Cycle Capacity 50 MW
Power Cycle Steam Rankine
Cooling Type Wet

Thermal Energy Storage

Storage Type 2-tank indirect
Storage Capacity (Hours) 9
Storage Description 60% Sodium Nitrate, 40% Potassium Nitrate.

The project data on these pages and in the downloadable CSV file is copyright (©) Institute for Advanced Sustainability Studies (IASS) and others 2022; data by Lilliestam@IASS, Thonig@IASS, Zang@CAS, Gilmanova@CAS and others. The data is licensed under a Creative Commons Attribution 4.0 International License.”